Instalace
Informace | ||
---|---|---|
| ||
Instalace Automation Studia trvá velmi dlouho, cca něco přes hodinu. Je to způsobeno velkým počtem malých souborů k instalaci. |
Instalátor vyžaduje starý .NET 2 a 3
Instalátor má všechny ostatní závislosti v sobě a doinstaluje si to sám.
Informace | ||
---|---|---|
| ||
Přepínače rozlišují malá a velká písmena. |
Přepínače instalátoru (převzato z helpu pro verzi 4.9):
Parameter | Explanation | Comment | Example |
---|---|---|---|
/L | GUI language | 1033 for English, 1031 for German | /L=1031 : Dialog boxes in German |
/R=Y | Program mode | Only "reduced mode" is currently available. It provides a simplified GUI. Dialog boxes with user interaction are hidden. | /R=Y |
/Log | Filename of the log file | The entire path must be specified for the installation log file, including the filename. This file is not generated until the installation is complete. While the installer is running, this file does not exist. | /Log=C:\Temp\InstallationProcess.log |
/INSTALL_SUFFIX | Expansion of the version label | The text set by the parameter is added to the Automation Studio version label. This makes it possible to install the same version of Automation Studio on a computer at the same time. The specified text must have a valid filename and is not permitted to contain spaces. | /INSTALL_SUFFIX=Test |
/D | Destination path | The destination directory for the installation is set with option /D. Option /D must always be the last parameter specified. | /D=C:\Program Files\BrAutomation |
Návratové hodnoty instalátoru:
0 - Bez chyby
1 - Instalace ukončena uživatelem
2 - Chyba během instalace
Troubleshooting Exit Code 2
The user running the installer is not an administrator.
The BrAddOn.ini file could not be found.
A Windows 2000 operating system is being used without SP4.
A Windows XP operating system is being used without SP2.
A process named "pviman.exe" is running.
A process named "pvimon.exe" is running.
A process named "pvitransfer.exe" is running.
A process named "pg.exe" is running.
Automation Studio is already installed and incompatible with the version being installed.
The installation directory is write-protected.
Licence na mendelu
/wiki/spaces/TECH/pages/18022689
B&R v současnosti neposkytuje aplikaci licenčního serveru pro plovoucí licence jako třeba Matlab nebo Solidowrks, pouze pevné licenční číslo.
Konfigurace
Po instalaci je třeba zadat licenční číslo (stačí pouze jednou, aktivuje se to pro všechny uživatele), asi by to šlo automatizovat, když zjistíme, kam se to uloží. Ověření licence probíhá online, takže PC musí být při zadávání čísla schopno zkontaktovat servery B&B.